The following products are either being phased out of production, or have been discontinued from production, or are only available to special order. Product information, where available, can be viewed by clicking on the links below. For full details of availability and compatibility with current products, please contact our engineers.
| 773 |
Discontinued Tattletale® magnetic switch. Closest equivalent is ETS30S. |
| A200-2(P)(C) |
Discontinued Modex Automation 2 channel annunciator, 96mm (w) x 48mm (h). |
| A200-3(P)(C) |
Discontinued Modex Automation 3 channel annunciator, 96mm (w) x 48mm (h). |
A200-4(P)(C)
A201-4(P)(C) |
Discontinued Modex Automation engine/generator controllers, 96 x 96mm DIN. The range also included special variants A203-4, A210-4, A211-4, A213-4, A215-4 and A217-4. The nearest equivalents are the Autostart AS7xx and AS731 controls. |
A301
(Alpha front label) |
Discontinued Modex Automation special variant of the Manustart controller. Superseded on Slingtons/Hallmark generators by the A302(OS) - see below. |
A302/A302OS
(Alpha front label) |
Discontinued Modex Automation special variant of the Keystart 9600 range. Standard Keystarts have a rear facia switch bank for selection of power supply (12 or 24VDC) and fault input polarity (open/close to +ve/-ve during fault), but the A302(OS) is 1) factory preset for 12 or 24 VDC, 2) fault inputs are preset at closed to negative on fault. Nearest equivalent to the A302 is the Keystart 9600; nearest equivalent for the A302OS (AC sensing overspeed trip) is the Keystart 9602. |
A401
(Alpha front label) |
A special variant of the AS700 produced for Slingtons/Hallmark generators. Differences from the AS700 include 1) a front label with Alpha branding 2) a manual mode output on pin 5 (instead of a magnetic pickup input), 3) different adjustment ranges for some timers, 4) the unit will NOT automatically start the engine if a mains fail occurs when the keyswitch is set to manual. Contact our sales office for availability. |
| A500 series |
Discontinued range of Modex Automation alarm / annunciator module, 96 x 96mm DIN. Many hardware variants were produced, each defined by a specification number (e.g. A110, A103). The A500 series was superseded by (but is not pin compatible with) the A800 (also now discontinued). |
| A600-6/A600-4 |
Discontinued Modex Automation engine/generator controller (A600-6) and AMF/ATS module (A600-4), specially produced for Dawson Keith Ltd. No direct equivalent. Closest equivalent is the AS7xx and AS731 controls. |
| A800 |
8 channel alarm/annunciator module. Production of this unit was discontinued in Jan 2006, but some stocks remain - contact our sales engineers for availability.
Web page
Sales bulletin |
| A86 |
Discontinued automatic engine/generator controller, used as the main control module in some older Murphy panels. Please contact our sales engineers for further info about the A 86 and replacement panels. |
| A900, MC900/MGC900 |
Engine/genset controllers and panels, production discontinued in 2005. Includes models A901, A902 and A903. More info:
- A900 controllers
- MGC900 genset panels |
| Alpha |
Alpha branded products produced by Modex Automation for Hallmark/Slingtons generators. See entries above for A301, A302 and A401. |
| AMACS GSM |
Discontinued GSM communication panel. Click here for info. |
| AP12 |
Discontinued alarm/annunciator module. Click here for info. |
| AS3000 |
Discontinued Autostart controller:-
Web page
Bulletin
Installation and operation |
| AS711 |
Discontinued Modex Automation engine/generator controller. Superseded by (and pin compatible with) the Autostart AS705. To program an AS711, use software model AS7CH. |
| AS720 |
Discontinued Modex Automation Autostart module:-
Bulletin
Installation and operation
The AS720 provided the same functionality as an AS710 controller plus mains AC under voltage monitoring and contactor control (e.g. using a UVR/PFR trip relay). |
| AS730 |
Autostart generator controller, production discontinued in July 2005. The AS730 has been superseded by the AS731. For technical details of the AS730, please visit our PDF literature index.
|
| AS731/AS732 |
Autostart generator controllers, production discontinued in Sept 2007. Further information:-
|
| ASM160 |
A MurCal (formerly Murphyswitch California) designed unit. Further info:-
Bulletin
Installation and operation
The ASM160 has been superseded by the ASM170.
|
| ASM200 |
A special MurphySwitch (California) designed unit, used only in Murphy Europe 200 series panels. Further info:-
Bulletin
Installation and operation
Typical wiring diagram |
| ASM260 |
A special MurphySwitch (California) designed unit, now discontinued. |
| AT67207 |
Bulletin
Installation and operation
The AT67207 was discontinued in Summer 2004 and has been superseded by the AT03069. The older AT67207 had two separate versions for 12V or 24V DC operation; the new AT03069 has a dual 12/24V capability but requires an extra negative DC supply connection to terminal 4. |
| BC100 series |
A discontinued range of constant current battery chargers, models BC101 through to BC108 were the predecessor of the BC700/BC701 series (also now discontinued - see below). 'B' option models had a 'boost' facility. Contact our engineers for further technical details. Closest equivalent is the SM82 range. |
| BC700/BC701 |
A range of constant current battery chargers, discontinued in mid-2004. BC700 models were for 12V systems, BC701 were fro 24V systems. Click here for a datasheet. Superseded by the SM82 range. |
BC0812, BC0824
BC1212, BC1224
BC1812, BC1824 |
Discontinued range of 8, 12 and 18 Amp (12 or 24 V) battery chargers. Nearest Murphy equivalent is the BC3012/BC1524 series. |
| BC1524, BC3012 |
15A/24V and 30A/12V high power battery chargers, now available as part of the Monitor range. For low ripple output alternatives (e.g. sealed batteries), see the Guardian range. |
| BCA series |
3 or 5A, 12 or 24V battery chargers, now available as part of the Sentry range. For low ripple output alternatives (e.g. sealed batteries), see the Sentinel range. |
| BGT1 series |
Discontinued Tankend™ fluid level controls.
Bulletin
Installation instructions
See fluid levels section for nearest equivalents. |
| CB32 |
Call out box. Click here for more info. |
| CD100 (Cascade) |
The predecessor to the Cascade CD101.
Old CD100 literature:-
CD100 bulletin CD100 installation |
| CS2001 |
Discontinued Selectronic Controller Scanner:-
Bulletin |
| CVT100 series |
Discontinued Modex Automation range of general purpose DC current and voltage trip relays, housed in an 11 pin plug-in case - click here to view a sales bulletin. No direct Murphy equivalent. |
| CVT500/501 series |
Discontinued range of general purpose current and voltage relays for use with DC (CVT500) and AC (CVT501) signals - click here for more info. No direct Murphy equivalent. |
| CVT503 |
Discontinued Modex Automation temperature control relay, for engine jacket heater control using a VDO temperature sender. No direct equivalent. |
| CVT504 |
Discontinued Modex Automation AC check-synch relay. No direct equivalent. |
CVT502, CVT506
and CVT508 |
Discontinued DC voltage relays (24VDC, 12VDC and 48VDC respectively). Several variations on these standard products were produced. There is no direct Murphy equivalent. |
| DCM series |
Discontinued Modex Automation motor speed controller. No equivalent. |
| DPC20 |
Discontinued Murphymatic® duplex pump controller. Click here to view bulletin (PDF format). |
| DS77 |
Discontinued dual speed switch. Contact our sales engineers for further info. |
| DT1000(V)(H) |
Discontinued Modex Automation 12 channel temperature indicator, 3 digit LED display, 48 x 96mm. |
| DT9600 |
Digital tachometer Swichgage, discontinued in 1999. Contact our sales engineers for further info. |
DT9800 series |
Discontinued range of digital tachometer Swichgages, including models DT9803, DT9804,
DT9805 and DT9806. Click here for links. |
| DV series |
Dump valves for scrubbers:-
Bulletin
Installation Instruction
The DV series has been superseded by DVU series. |
| DV850, DV875 |
Pneumatically controlled dump valves used in separator/scrubber applications. These units were discontinued in June 2002, and are superseded by models DVU150 and DVU175. |
| ECD series |
A range of residual current earth leakage detector relays, discontinued in Feb 2008. More info > |
| Econostart ES8000 |
An automatic mains fail module, originally designed as an enhancement to the Keystart series of manual controls. Production was discontinued in October 2003, but some stocks remain - contact us for availability. |
| ELD series |
Discontinued range of residual current earth leakage detector relays. Standard models were the ELD2 (20mS fast response), ELD4 (slower, fixed trip times) and ELD5 (adjustable time response), but many variants and specials were also produced. The ELD range was superseded in Jan 2002 by a reduced number of standard ECD models, but this range has also subsequently been discontinued. |
| EN204 |
Discontinued four-function annunciator. More info > |
| ERC range |
A range of larger diameter core balance transformers, optionally used with ELD and ECD earth current detector relays. ERC transformers were discontinued in March 2007. |
| ES2DP30 |
Discontinued dual pressure sender (for EG series electric gages, etc), 30 psi. No direct equivalent. |
| ESI3 |
3 way Engine Status Indicator, comprising LED bar-graph indication of oil pressure, engine temperature and battery voltage. Production was discontinued in March 2006, but some stock remain - please contact our engineers for availability.
More info > |
| ET25 |
Discontinued Modex Automation encapsulated timer (delay on energisation with blade connectors). No Murphy equivalent. |
| FP350 |
Discontinued Murphymatic® NFPA-20 Type Fire Pump Controller |
| FSV |
Discontinued fire shutoff valve:-
Bulletin |
| GPM92 |
Glow plug control module that is in the process of being phased out. Contact our sales engineers for details of operation and availability. |
GsmControl-A
GsmControl-X |
GSM modem communication modules, discontinued in September 2007:-
Bulletin
Quick start guide
|
| GV733 |
Discontinued display for Cummins G-drive RS485 modbus systems. More info > |
| H33-SS |
Discontinued Murphymatic® lift pump control system. Click here to view bulletin (PDF format). |
| HD35 |
Discontinued digital hoursrun counter. Click here for sales bulletin. |
| HFT series |
Discontinued Modex Automation High Frequency Trip relay. Click here for more info. See also OFR range. |
| HT100 |
Discontinued Modex Automation humidity trip relay (11 pin plug in). Contact our sales engineers for further info. |
| ID500 |
Discontinued Modex Automation film scanner for packaging equipment. No direct equivalent. |
| IFD95 |
Discontinued ignition failure device. Click here to view bulletin (PDF format). |
| Keystart 7201 |
Keystart engine controller, discontinued in July 2005:-
Bulletin
Installation Instructions
Closest equivalent is the Keystart 7210/7211 |
| Keystart 9000 / 9600 series |
Discontinued 72mm and 96mm Keystart range with blade terminal connection:-
Bulletin
Installation reference sheet
The closest equivalent Keystart models are the 7210 series (replacing 72mm 9000 series) and 9620 series (replacing the 96mm 9600 series). See also
Keystart 7210/9610 - retrofitting guide for older Keystarts.
|
Keystart
9003, 9004, 9005 |
Discontinued Keystart units, based on the Keystart 9000 range but with a timed preheat output and connection via 2 x 10 way two-part type terminal blocks. Contact our sales engineers for further info. |
Keystart
9006, 9007 |
Discontinued variants of the Keystart 9000 range. Model 9006 is based on model 9001, but can be adjusted for use with a wider (higher) range of magnetic pickup (engine speed sensing) frequencies. Model 9007A is based on model 9006, but is designed for use with a remote Off-Run-Start switch (with a blind grommet in place of the usual Keyswitch). |
Keystart
9610, 9611 |
Superseded by Keystart 9620 & 9621 in July 2009.
9610/9611 installation instructions
|
Keystart
9650, 9651, 9652 |
Variants on the discontinued Keystart 9600 series. Operation and connection is as 9600, 9601 and 9602, but the run output is designed for use with energised-to-stop fuel systems - contact our sales engineers for further info. |
Keystart
9700 series |
Discontinued 96mm Keystart range with two-part screw terminal blocks at the rear:-
Bulletin (PDF)
Installation reference Sheet (PDF)
These models were superseded in 2005 by the Keystart 7210 and 9610 series. See also
Keystart 7210/9610 - retrofitting guide for older Keystarts (PDF).
|
| L1150, L1250 |
Level controls for scrubbers, discontinued in Feb 2004, but parts/repairs available at current usage until 2006/07. Contact our sales engineers for further info and availability. |
| L1200 |
Discontinued level switch for scrubbers:-
Web page
Sales bulletin
Installation instructions The L1200 has been superseded by the LS200 series.
|
| LFT series |
Discontinued Modex Automation Low Frequency Trip relay. Click here for more info. No direct equivalent. |
| LLS series |
Discontinued lead line pressure switch:-
Bulletin
Installation Instructions
|
| LR900, LR901, LR900-EX |
Discontinued level maintainers/switches:-
Bulletin (9.3Mb PDF file)
Closest equivalent models are LR857 or LM2000.
|
| Manustart |
Discontinued Modex Automation engine controller, manual start. Superseded by (but not pin compatible with) the Keystart range. |
| Mark II series |
Discontinued range of digital fault annunciators, used mainly in gas compressor applications:-
Sales bulletin
See our compressor controls section for a range of replacement controllers. |
| MDM45 |
Discontinued 4 - 20mA loop monitor Swichgage®:-
Sales bulletin
Installation instructions
Some stock remain as of July 2003, with spare parts stocks envisaged to continue until 2006. |
Microstart
MS1A, MS1D |
Discontinued Modex Automation full AMF generator controller. Models included MS1A (for use with AC coiled contactors) and MS1D (for use with DC coiled contactors). Models with a 'C' suffix are fitted with a remote communications option. Further info:
Sales bulletin
Installation & connection
Programming
Operation
Remote alarms ('R') option and relay board (MSRP)
RS232 Communications ('C') option
Microstart was superseded by (but not pin compatible with) the Autostart AS7xx, AS731 and AS732 controls.
|
| MFU series |
Discontinued Modex Automation Mains Failure relays (3 phase, no neutral). Click here for more info. Superseded by PFR range. |
MC900/MGC900/
A900 |
Engine/genset controllers and panels, production discontinued in 2005. More info:
- A900 controllers
- MGC900 genset panels |
| MP series |
Discontinued Murphymatic® electric motor pump controller. Please contact our sales engineers for further details. |
| MS400 |
Phased out / discontinued Selectronic Microcontroller. Click here for info. |
| MS500 |
Phased out / discontinued Selectronic Microcontroller. Click here for info. |
| MS510 |
Phased out / discontinued Selectronic Microcontroller Accessory board. Click here for info. |
| MSV-375 |
Discontinued fuel shutoff valve for diesel engines. Click here to view bulletin. |
| MTHM90 |
Discontinued digital tachometer/hourmeter. Nearest equivalent is the MTH6. |
| OFR501 |
As discontinued OFR500 but with either 49 - 52 Hz or 400 - 475 Hz adjustment range. No direct Murphy equivalent. |
| OLR500 |
3 phase AC overload (over current) relay, 110 or 240VAC auxiliary power supply. No Murphy equivalent. See also OLR600. |
| OLR600, OLR605 |
Discontinued AC over current relays. No direct Murphy equivalent. The OLR600 was for use for use with star-connected 5 Amp CTs; the OLR605 was for use with delta-connected 5 Amp CTs. |
| OPLFNC |
Discontinued 4.5" pressure Swichgage with normally closed contacts. Click here for installation instructions (PDF view). |
OST100/OST101 UST100/UST101 |
Discontinued Modex Automation over/under speed/frequency trip relays. Click here for a bulletin. 11 pin plug in case, 12 or 24V DC auxiliary supply, 110/240VAC input, 40 - 70Hz adjustment range. No Murphy equivalent. |
| OVT series |
Discontinued Modex Automation Under Voltage Trip relays. Click here for more info. Superseded by OVR range. |
| OVR101, OVR501 |
Discontinued single phase (OVR101) and 3 phase (OVR501) 110VAC ph-N variants of the OVR over voltage relay. |
| PEM series |
Pilot Earth Monitoring relay (for checking the low resistance integrity of earth conductors), previously produced by Brian Bennett Engineering and Modex Automation. As of July 2004, production is discontinued but some stocks remain - please check for availablity. |
| PFR300R |
Discontinued 3 phase, 3 wire phase failure relay for use with 380/400/415VAC phase to phase systems - click here for a product bulletin. Nearest equivalent is the PFR500R. |
| PFR501, PFR501R |
Discontinued variants of the PFR500 series phase failure relays, for use with 3 phase, 3 wire (no neutral), 200VAC phase to phase systems. There is no direct Murphy equivalent, but 3 phase, 4 wire relays such as the UVR501 (110VAC phase to neutral) may be suitable. |
| POR500/501 |
Discontinued over voltage (energised on low voltage) equivalent of the PFR series 3 phase, 3 wire AC trip relays |
| PS640 |
Microprocessor based irrigation control panel:-
Sales bulletin
Installation instructions
|
| PS660 |
Microprocessor based irrigation control panel:-
Sales bulletin
Installation instructions |
| PV100 |
The original PowerView™ display module, superseded in March 2007 by the PV101.
|
| PXMS / PXDGS |
Pressure transmitters, discontinued in 2005:-
Web page
Sales bulletin
Installation instructions
The PXMS 4-20mA transmitters are superseded by the PXT series. There is no direct equivalent for the PXDGS series 1-5V transmitters. |
| RMU16 |
Discontinued remote monitoring unit.
Installation Instruction |
| RCR/S and RCR/L |
Discontinued elastic retaining straps for the Modex Automation range of plug-in timers and relays. |
| S1012, S1024 |
Discontinued range of 10A/12V and 10A/24V battery chargers:-
Bulletin
The S10 range has been superseded by the BC1524 and BC3012 range. |
| S1400 |
Discontinued Microcontroller for use in gas compressor applications. More info:-
Bulletin
Installation Instruction
Information for four stage engine driven compressor applications
Information for four stage electric motor driven compressor applications
The S1400 has been superseded by the S1501 series. |
| S1500 |
Discontinued Microcontroller for use in gas compressor applications. More info:-
Bulletin
Installation instructions
The S1500 has been superseded by the S1501 series.
|
| S260 |
Selectronic S260 controller, a discontinued product of Murphyswitch California. Limited spares may be available - please contact our engineers. |
| SCC series |
Discontinued satellite communication system. Contact our sales engineers for further info. |
| SD35HL |
Discontinued digital tachometer with underspeed and overspeed switches. Check with your Murphy representative for availability. More info:-
Bulletin/Installation |
| SHD45 |
Digital tachometer/hourmeter, panel mount, 4.5 inch diameter:-
Bulletin
Installation instructions
The SHD45 series was discontinued in mid 2003, and superseded by the SHD30-45.
|
| SIM007 |
Discontinued Modex Automation temperature simulators with an open board construction. The nearest equivalent is the (DIN cut-out mounted) SM200 below. |
| SM200, SMT200, SM200-TR |
Ex-Modex Automation temperature simulators, designed for form-fill, film and bag sealing (packaging) equipment. These units are still in production. Click here for a PDF bulletin (465Kb file), or contact our sales engineers for full information. |
| SM series |
Discontinued Tankend™ fluid level controls.
Bulletin
Installation instructions See Fluid levels section for nearest equivalents.
|
| SM7 |
Discontinued Modex Automation temperature simulators, 8 pin plug in. Nearest equivalent is the (DIN cut-out mounted) SM200 above. |
| SS100 |
Discontinued speed switch. Contact our sales engineers for further info. Closest equivalent is the SS300. |
| ST4X4, ST10HC, STA110, STA16-PB, |
Discontinued variants of the ST series annunciators. |
| STAS, STASTD |
Discontinued diode and diode/time-delay packages, accessories for ST series annunciators. No direct equivalent. |
| TC100, TC101, TC100X, TC101X TC100Z, TC100RT |
Ex-Modex Automation temperature controllers, 8 pin (octal) plug-in case. The range was discontinued when the plug-in casing was made obsolete. There is no direct Murphy equivalent. The closest equivalent is the TC200D temperature controller - please contact our sales engineers for further info. |
| TC200D |
Ex-Modex Automation temperature controllers. Production of these controllers has been discontinued, but some variants remain in stock - please check for availability. Click here for a technical bulletin, or contact our sales engineers for further information. |
| TC400 |
Discontinued Modex Automation temperature controllers, designed for mounting in a 44 x 44mm (DIN standard) panel cut-out. Closest equivalent is the TC200D above. |
TC500(D)(T)
TC1000(D)(T) |
Ex-Modex Automation temperature controllers, designed for mounting in a 92 x 92mm (DIN standard) panel cut-out. The TC500 series had a rotary dial to set temperature; the TC1000 used three decade thumbwheel switches. The 'D' option provided a 'deviation' meter (to indicate deviation between set and actual temperatures). The 'T' option provided an alarm relay that tripped at at a pre-set number of degrees above or below the set temperature (as detailed on the label). There is no direct Murphy equivalent. The closest equivalent is the TC200D temperature controller - please contact our sales engineers for further info. |
| TD35 |
Dual channel digital temperature Swichgage. Production discontinued in mid 2003 but some stocks remain: please contact our engineers for price and availability. Further information (PDF format) :-
Bulletin
Installation instructions
|
| Thermocouples |
The Murphy TC, RTD and RTDT ranges of thermocouples, RT probes and transmitters for engine temperature sensing are available from catalogue section 10. For information on the discontinued range of Modex Automation thermocouples (mostly J and K type for use in the process control industry), click here. Several thousand variations of Modex thermocouple were produced, each type identified by a 4 figure tag number - please contact our sales engineers for details of each variant. |
| TR100, TR200, TR300, TR501, TR1400 |
Ex-Modex Automation delay on energisation time relays with 8 and 11 pin plug-in cases. The range included models TR100, TR100Z, TR101, TR200, TR300, TR300Z, TR301, TR301Z, TR302, TR1400, TR1401. Click here to view bulletin (PDF file). The range was discontinued when the plug-in casing was made obsolete. |
| TR25 |
Ex-Modex Automation, 8 pin plug-in, delay on energisation timer. AC supply variants were discontinued in Jan. 2000, DC variants in Jan. 2003. Click here to view bulletin. |
| TR24, TR26, TR27 |
Discontinued variants of the TR25. Contact our sales engineers for full information. |
| TR40 |
Ex-Modex Automation, 8 pin plug-in, interval timer. AC supply variants were discontinued in Jan. 2000, DC variants in Jan. 2003. Click here to view bulletin. |
| TR900 |
Ex-Modex Automation three attempt start timer, 8 pin plug-in. Many variants were produced. Discontinued as for TR100. No direct equivalent. Click here to view bulletin (PDF file). |
| TR1100 |
Ex-Modex Automation true delay on de-energisation timer, 8 pin plug in. Discontinued as for TR100 above. No direct equivalent. Click here to view bulletin (PDF file) |
| TR1500 |
Ex-Modex Automation asymmetric recycling timer, 8 pin plug in. Discontinued as for TR100 above. No direct equivalent. Click here to view bulletin (PDF file) |
| TRC200D |
Discontinued, special variant of the TRC200 (see below) produced for Circuit Engineering Marketing Co. (CEMCO) Ltd. The unit allowed remote selection (by panel switch) of 2 set temperatures (for duty and standby use). There is no direct equivalent. |
TRC200
TRC200-T |
Ex-Modex Automation temperature controllers, now discontinued from production. Contact our sales engineers for full information. |
TRC500
TRC500-T |
Discontinued Modex Automation temperature controllers, 92 x 92mm DIN cut-out mounted with LED display indication of set/actual temperature. Nearest equivalent is the TRC200(-T). |
TT12Z-TP/
TT24-TP |
Discontinued Modex Automation temperature controllers, with a 'two-tier' open PCB construction. Click here for datasheet. Nearest equivalent is the front-of-panel mounted TC200D. |
| TTDJ |
Digital fault annunciator:-
Web page
Bulletin
Installation instructions
Product is to be phased out - check stock availability. Consider using the TTD series as an alternative. |
| UST100/UST101 |
See OST above. |
| UFR500 |
Discontinued AC under frequency relay - click here for more info. No direct Murphy equivalent. |
| UFR501 |
Similar to discontinued UFR500 but with 48 - 51 Hz or 325 - 400 Hz adjustment range. |
| UT1 series |
Discontinued Tankend™ fluid level controls.
Bulletin
Installation instructions
See Fluid levels section for nearest equivalents. |
| UVT series |
Discontinued Modex Automation Under Voltage Trip relays. Click here for more info. Superseded by UVR range. |
| VR300 |
Discontinued Modex Automation AC under-voltage trip relay, 8 pin (octal) plug in case. The devices were factory set (internally) to trip at a customer specified voltage. The closest equivalent is the DIN rail mounted, user-adjustable UVR100/101. |
| VS2N |
Pneumatic version of the VS2 vibration switch. No direct equivalent. |